Monitoring
Sync logs
The record of every OLT and ONU sync: when, who asked, how long it took and why one failed.
Who can use it:
Super Admin, NOC Admin, Employee
Open this page in the app
What this page is for #
A record of every sync: which OLT or ONU, when, who or what started it, how long it took, how many ONUs it read, and the result. Come here when data looks old or an OLT shows “Failed”.
- 1 Trigger: Schedule (automatic), Manual (someone pressed Sync) or API (another system asked).
- 2 Status: Success, Partial, Failed or Running.
- 3 Dates: pick From / To or a quick range.
- 4 Steps opens the detail: each part of the sync and the seconds it took.
What the results mean #
| Result | Meaning | What to do |
|---|---|---|
| Success | Everything was read. | Nothing. |
| Partial | The sync finished but some data could not be read (for example optical power was skipped to stay within the time limit). | Read the message. If it happens every time, tell your administrator. |
| Failed | The OLT did not answer, or the sync was stopped or ran out of time. | Read the message, then Test connection on the OLT page. |
| Running | In progress now; the message shows the current step. | Wait, or watch it in the Sync queue. |
Common tasks #
See why an OLT's sync failed
- Set the status filter to Failed.
- Find the OLT and read the message: it names the last step, the time used and usually the fix.
- Typical messages: No response (OLT unreachable or wrong SNMP community), timed out (the OLT is slow or very large), Stopped by … (someone stopped it).
Who refreshed this customer's ONU?
- Set the trigger to API or Manual and the date.
- Rows started from DCM show Pulled by (the DCM user) and Customer.
Check that the automatic syncs are running
- Set the trigger to Schedule and the range to Today.
- You should see each active OLT about once per sync interval. Nothing today? See Troubleshooting.
Related topics
Sync queue
What is syncing right now and what is waiting. Reorder, run next, stop or remove a job.
OLT page
One OLT in detail: sync status, CPU / memory, PON ports with laser readings and the ONU list.
Troubleshooting & FAQ
Quick answers: sync failed, no optical power, a menu is missing, ONU not found, and more.
Activity log
Who added, changed or deleted sites, cables, devices, customers and ONUs, and what exactly changed.
Finished this topic?